Technical data
Control cable
according to UL style 2587 – CSA VDE 0295 cl.5
Operating temperature
Fixed installation -5 C°/+90 C°
Operating voltage
Uo/u 600 V
Voltage test
3.000 V
Radius of curvature
12 times the external diameter
Cable structure
Conductors
thin strands in red copper according to VDE 0295 cl.5 IEC 228 cl.5
blacks numbered with yellow / green
External sheath
· PVC special oilproof TM5 UL type 1581 standard, self-extinguishing and flame retardant according to IEC 332.1 – UL FT2
· color grey RAL 7001
Utilization
Multi-polar cable built to standards to meet the needs of manufacturers of machinery for export to countries that adopt ULCSA-HAR regulations. It can be used in drag chain, with slow movements and without sudden accelerations.
Date of update 20/07/2017
code | cable formation | external diameter |
---|---|---|
EQ3N | 3x0,5 | 6,1 |
EQ3N | 4x0,5 | 6,7 |
EQ3N | 5x0,5 | 7,5 |
EQ3N | 7x0,5 | 8,2 |
EQ3N | 12x0,5 | 10,9 |
EQ3N | 18x0,5 | 13,0 |
EQ3N | 25x0,5 | 15,2 |
EQ3N | 34x0,5 | 17,6 |
EQ3N | 50x0,5 | 21,3 |
EQ3N | 3x0,75 | 6,6 |
EQ3N | 4x0,75 | 7,3 |
EQ3N | 5x0,75 | 8,1 |
EQ3N | 7x0,75 | 8,9 |
EQ3N | 12x0,75 | 11,9 |
EQ3N | 18x0,75 | 14,2 |
EQ3N | 25x0,75 | 16,5 |
EQ3N | 34x0,75 | 19,2 |
EQ3N | 50x0,75 | 23,2 |
EQ3N | 3x1 | 6,9 |
EQ3N | 4x1 | 7,7 |
EQ3N | 5x1 | 8,5 |
EQ3N | 7x1 | 9,4 |
EQ3N | 12x1 | 12,6 |
EQ3N | 18x1 | 15,0 |
EQ3N | 25x1 | 17,5 |
EQ3N | 34x1 | 20,4 |
EQ3N | 50x1 | 24,7 |
EQ3N | 3x1,5 | 8,2 |
EQ3N | 4x1,5 | 9,1 |
EQ3N | 5x1,5 | 10,1 |
EQ3N | 7x1,5 | 11,1 |
EQ3N | 12x1,5 | 14,9 |
EQ3N | 18x1,5 | 17,9 |
EQ3N | 25x1,5 | 20,9 |
EQ3N | 34x1,5 | 24,3 |
EQ3N | 50x1,5 | 29,5 |
EQ3N | 3x2,5 | 9,7 |
EQ3N | 4x2,5 | 10,7 |
EQ3N | 7x2,5 | 13,2 |
EQ3N | 12x2,5 | 17,8 |
EQ3N | 18x2,5 | 21,3 |
EQ3N | 25x2,5 | 24,9 |
EQ3N | 4x4 | 12,5 |
EQ3N | 7x4 | 15,4 |
EQ3N | 4x6 | 14,0 |
EQ3N | 7x6 | 17,3 |
EQ3N | 4x10 | 16,2 |
EQ3N | 4x16 | 23,2 |
EQ3N | 4x25 | 28,1 |
We design and manufacture electrical cables for automation to customer specifications